The CQC1 series AC contactors are designed by CHAC Electric for use in circuits with an AC frequency of 50Hz (or 60Hz), a rated working voltage of 690V, and a rated working current ranging from 9A to 800A. They are primarily used for remotely making and breaking circuits and for the frequent starting and control of AC motors. These contactors can also be combined with thermal overload relays to form electromagnetic starters, providing protection for circuits that may experience overloads. The CQC1 series ensures reliable and efficient operation, making it an ideal choice for industrial applications where precise motor control and circuit protection are essential. It complies with IEC 60947-4, GB/T 14048.4, IEC 60947-5, and GB/T 14048.5 standards.

    Scope of application and use

    COC1-09~800series AC contactors(hereinafter referred to as contactors)are mainly used for AC 50 Hz(60Hz) In the circuit with rated working voltage of 690V and rated working current of9A~800A,it is used for making and breaking the circuit remotely And frequently starting and controlling AC motors; And can form an electromagnetic starter with an thermal overload relay,To protect circuits that may be overloaded.Comply with IEC 60947-4,GB/ T14048.4, IEC60947-5, GB/T14048.5.

    Applicable environment

    ◆Operating temperature

    Standard operating temperature:-25℃~+40℃

    Limit service temperature:-40℃~+70℃

    Storage temperature:-60℃~+80℃

    ◆Use altitude

    Normal use altitude:< 2000m

    Limit service altitude:< 5000m

    ◆Pollution level: pollution level 3

    ◆Installation category: Class ll

    ◆Installation method:screw installation.35mm and 75mm can also be used for 09A~95A products.

    Structural features

    ◆The action mechanism is direct acting, and the contact is double break point;

    ◆Strong combination function, and the mounting surface can be equipped with accessories;

    ◆Reversible mechanism can be installed on both sides to form a reversible contactor; Auxiliary contact group(F4) and air delay head (S4)(09A~95A)can be installed above; Auxiliary contact group(F4) and air delay head (S4)(115A~800A)can be installed on the right side;

    ◆Protective type Protection grade IP20;

    ◆The contactor shall comply with the provisions of use categoryAC-3,operation level 0.l and load 60% value or equivalent national standard;

    ◆The contactor can be equipped with thermal overload relay,mechanical interlocking module,auxiliary contact,etc .To expand product functions.

    Model and Meaning

    2.Model and Meaning.jpg

    Note 1: 09A~95A is in the form of auxiliary contact, and 115A~800Aisconventional without auxiliary10 indicates three normally open main contacts and one normally open auxiliary contact (32A and below)01 represents three normally open main contacts and one normally closed auxiliary contact (32A and below)11 represents three normally open main contacts, one normally open and one normally closed auxiliary contact (40~95A).

    Technical parameters

    09~95A performance index

    CQC1-09

    COC1-12

    COC1-18

    COC1-25

    COC1-32

    COC1-40

    COC1-50

    COC1-65

    CQC1-80

    CQC1-95

    Rated working current le,A(AC-3)

    400V

    9

    12

    18

    25

    32

    40

    50

    65

    80

    95

    690V

    6.6

    8.9

    12

    18

    21

    34

    39

    42

    49

    49

    Agreed free air heating current lth (A)

    25

    25

    25

    40

    40

    65

    80

    80

    125

    125

    Rated working voltage Ue (V)

    380/400、660/690

    Rated insulation voltage Ui (V)

    690V

    AC-3(6le、le)

    Electrical life (times)

    200×104

    200×104

    200×104

    200×104

    200×104

    200×104

    200×104

    200×104

    200×104

    200×104

    Frequent operation(h)

    1200

    1200

    1200

    1200

    600

    600

    600

    600

    600

    600

    AC-4(6le、6le )

    Electrical life (times)

    20×10

     

     

     

     

     

     

     

     

     

    Frequent operation(h)

    300

    Rated working current le(A)

    380/400V

    3.5

    5

    7.7

    8.5

    12

    18.5

    24

    28

    37

    44

    660/690V

    1.5

    2

    3.8

    4.4

    7.5

    9

    12

    14

    17.3

    21.3

    Mechanical life (times)

    1000×104

    800×104

    600×104

    Auxiliary contact

    Agreed free air heating current lth(A)

    10

    Electrical life (times)

    AC-15(360VA)

    100×104

    80×104

    60×1043

    DC-13(33W)

    Minimum load that can be connected

    24V 10mA

    Coil

    Rated control supply voltage Us (V)

    AC(50Hz/60Hz)24、36、110、220、380;DC:24、48、110、220

    pull-in voltage

    85%~110%Us

    Release voltage

    20%~75% US(AC)10%~75% Us(DC)

    50Hz AC coil power (VA)

    start

    65

    65

    65

    100

    100

    200

    200

    200

    200

    200

    Sorption

    8

    8

    8

    11

    11

    20

    20

    20

    20

    20

    DC coil power (w)

    start

    11

    11

    11

    13

    13

    22

    22

    22

    22

    22

    Sorption

    Wiring capacity of termina mm²(min/max)

    Non prefabricated end cord

    1 piece

     1/4

    1.5/6

    1.5/10

    2.5/10

    2.5/25

    4/50

    2 pieces

     1/4

    1.5/6

    1.5/6

    2.5/10

    2.5/16

    4/25

    Flexible wire with prefabricated end

    1 piece

     1/4

     1/6

     1/6

     1/9

    2.5/25

    4/50

    2 pieces

    1/2.5

     1/4

     1/4

    1.5/6

    2.5/10

    4/16

    Non prefabricated end hard wire

    1 piece

     1/4

    1.5/6

    1.5/6

    1.5/10

    2.5/25

    4/50

    2 pieces

     1/4

    1.5/6

    1.5/6

    1.5/10

    2.5/16

    4/25

    Tightening torque of main circuit wiring

    N·M

    1.7

    2.5

    5

    9

    115A-800A performance index

    technical parameter

    CQC1-115

    CQC1-150

    CQC1-185

    CQC1-225

    CQC1-265

    CQC1-330

    CQC1-400

    CQC1-500

    CQC1-630

    CQC1-800

    Rated working current le(A)

    AC-3

    400V

    115

    150

    185

    225

    265

    330

    400

    500

    630

    800

    690V

    86

    107

    118

    135

    172

    225

    305

    355

    460

    485

    AC-4

    400V

    52

    60

    79

    85

    105

    117

    138

    147

    188

    242

    690V

    49

    57

    69

    82

    98

    107

    135

    145

    170

    215

    Maximum rated power of controllable three-phase squirrel cage motor Pe (k)

    AC-3

    400V

    55

    75

    90

    110

    132

    160

    200

    250

    335

    450

    690V

    80

    100

    110

    129

    160

    220

    280

    335

    450

    475

    AC-4

    400V

    25

    30

    40

    45

    55

    63

    75

    80

    100

    129

    690V

    45

    51

    63

    75

    90

    100

    129

    140

    160

    200

    Agreed free air heating current lth (A)

    200

    200

    280

    280

    360

    360

    580

    580

    850

    850

    Rated working voltage Ue (V)

    400、690

    Rated insulation voltage Ui (V)

    690

    AC-3

    Electrical life (times)

    60×104

    50×104

    30×104

    20×104

    15×104

    Frequent operation (h)

    600

    300

    150

    AC-4

    Electrical life (times)

    15×104

    8×104

    5×104

    3×104

    Frequent operation (h)

    150

    Mechanical life (times)

    300×104

    100×104

    60×104

    Auxiliary contact

    Agreed free air heating current lth (A)

    10

    Electrical life (times)

    AC-15(360VA)

    60×104

    50×104

    30×104

    15×104

    DC-13(33W)

    Coil parameters

    Rated control supply voltage Us (V)

    AC50HZ:24、48 110 230(220)240 (double coil energy-saving type(380)

    AC50HZ:48、110 230(220)240 (double coil energy-saving type(380)

    pull-in voltage

    85%~110%Us

    Release voltage

    20%~75%Us

    coil power (VA)

    start

    560

    800

    750

    1000

    1100

    1600

    Sorption

    45

    55

    8

    12

    16

    20

    Pickup time (ms)

    23~35

    20~35

    30~65

    40~75

    40~80

    50~100

    Release time (ms)

    5~15

    7~15

    100~170

    100~170

    100~200

    130~230

    Main circuit connection capacity

    Copper conductor

    Number of roots

    1

    1

    1

    1

    1

    1

    2

    2

    -

    Conductor section mm

     

    120

    150

    185

    240

    240

    150

    240

    -

    Copper bar

    Number of roots

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    Dimension mm

    20×3

    25×3

    25×3

    32×4

    32×4

    30×5

    30×5

    50×5

    60×5

    60×5

    Auxiliary circuit contrd circuit

    Flexible cord
    mm²

    1

    2.5

    2

    Hard wire mm²

    1

    4

    2

    Appearance and installation dimensions

    CQC1-09 12、18、25、32

    3.CQC1-09 12、18、25、32.jpg

    Unit:mm

    Contactor model

    Amax

    Bmax

    Cmax

    a

    C1

    C2

    CQC1-09、12

    47

    76

    82

    35±0.50

    113

    133

    CQC1-18

    87

    118

    138

    CQC1-25

    57

    86

    95

    40±0.50

    126

    146

    CQC1-32

    100

    131

    151

    Note: C1:CQC1+F4 C2:CQC1+S4

    CQC1-40、50、65、80、95

    4.CQC1-40、50、65、80、95.jpg

    Contactor model

    Amax

    Cmax

    C1

    C2

    CQC1-4011-6511

    77

    116

    145

    165

    CQC1-8011~9511

    87

    127

    175

    195

    Note:C1:CQC1+F4 C2:CQC1+S4

    C0C1-115~330 overall dimensions and installation dimensions [tolerance: ± 1mm]

    5.C0C1-115~330 overall dimensions and installation dimensionsltolerance ± 1mm].jpg

    CQC1

    a

    P

    Q

    Q1

    S

    Φ

    f

    b

    b1

    M

    N

    c

    L

    G

    H

    Φ1

    G1

    Z

    Y

    X1

    ≤500V

    >500V

    115

    163.5

    37

    29.5

    60

    20

    M6

    131

    162

    137

    147

    124

    171

    107

    80

    120-106

    6.5

    106

    13.5

    44

    10

    15

    150

    163.5

    40

    26

    57.5

    20

    M8

    131

    170

    137

    150

    124

    171

    107

    80

    120-106

    6.5

    106

    13.5

    44

    10

    15

    185

    168.5

    40

    29

    59.5

    20

    M8

    130

    174

    137

    154

    127

    181

    113.5

    80

    120-106

    6.5

    111

    13.5

    44

    10

    15

    225

    168.5

    48

    21

    51.5

    25

    M10

    130

    197

    137

    172

    127

    181

    113.5

    80

    120-106

    6.5

    111

    13.5

    44

    10

    15

    265

    205

    48

    39

    66.5

    25

    M10

    147

    203

    145

    180

    147

    213

    141

    96

    120-106

    6.5

    140

    20.5

    38

    10

    15

    330

    213

    48

    43

    74

    25

    M10

    147

    209

    145

    184

    158

    219

    145

    96

    120-106

    6.5

    154.5

    20.5

    38

    10

    15

    Note: f is the space required for coil replacement

    X1 is the minimum electrical clearance [Flying Fox distance)the same as below

    CQC1-400-500 overall dimensions and installation dimensions(tolerance: ± 1mm)

    6.CQC1-400-500 overall dimensionsand installation dimensions.jpg

    CQC1

    a

    P

    Q

    Q1

    S

    Φ

    f

    b

    b1

    M

    N

    c

    L

    G

    G1

    Φ1

    H

    Y

    X1

    ≤500V

    >500V

    400

    213

    48

    43

    74

    25

    M10

    151

    206

    209

    181

    158

    219

    145

    80(66-102)

    170(156-192)

    8.5

    180

    19.5

    15

    20

    500

    233

    46

    46

    77

    30

    M10

    169

    238

    209

    208

    172

    232

    146

    80(66-102)

    170(156-210)

    8.5

    180

    39.5

    15

    20

    CQC1-630-800 overall dimensions and installation dimensions(tolerance: ± 1mm)

    7.CQC1-630-800 overall dimensionsand installation dimensions.jpg

    CQC1

    a

    P

    Q

    Q1

    S

    Φ

    f

    b

    b1

    M

    N

    c

    L

    G

    H

    Φ1

    Z

    Y

    X1

    ≤500V

    >500V

    630/800

    309

    80

    60

    89

    40

    M12

    201

    304

    280

    264

    202

    255

    155

    180(100-195)

    180

    10.5

    60.5

    68.5

    20

    30

    CQC1 Series Accessories

    Quick selection table/specification

    8.CQC1 Series Accessories.1.jpg8.CQC1 Series Accessories.3.jpg

    Specification of auxiliary contact [air delay type]

    model

    Delay range

    Number of delayed contacts

    Delay mode

    Hook mode

    S4-20

    0.1s~3s

    1NO+1NC

    Power on delay

    Top hanging

    S4-22

    0.1s~30s

    S4-24

    10s~180s

    S5-20

    0.1s~3s

    Power off delay

    S5-22

    0.1s~30s

    S5-24

    10s~180s

    8.CQC1 Series Accessories.2.jpg8.CQC1 Series Accessories.4.jpg

    Auxiliary contact specification

    model

    Number of contacts

    Hook mode

    Normally open [NO]

    Normally Closed [NC]

    F4-40

    4

    0

    C0C1-09~95 series contactors are top mounted
    CQC1-115-800 series contactors are side mounted

    F4-31

    3

    1

    F4-22

    2

    2

    F4-13

    1

    3

    F4-04

    0

    4

    F4-20

    2

    0

    F4-11

    1

    1

    F4-02

    0

    2

    Leave Your Message

    Send Inquiry

    The service network covers more than 50 countries and regions